Estidama tool
Compute the uplight percentage of your exterior scheme against the lighting-zone limit, check boundary illuminance, and work through the interior and control requirements the credit also carries.
Completion
How much of the check is established. It tracks your working file — it is not a statement that the credit is awarded, which only the reviewing authority can make.
60%
3/5 steps complete
Project
🧪 Loaded with an example
The figures below are illustrative, so you can see what the tool returns before entering your own. They are not typical values and not a recommendation — replace them with your project’s numbers.
↳ In this example the facade uplighters push the raw upward flux ABOVE the 5% LZ3 limit, but the scheme still passes at ~4.1% once only the light actually leaving the site is counted. Both figures are shown, because the difference between them is a design argument you have to be able to defend.
Boundary illuminance and per-luminaire upward flux come from the photometric calculation and the manufacturer IES files for the specified luminaires. This tool aggregates and compares them; it does not model light and cannot check the figures you enter.
Every project must be classified under one of these zones.
| Zone | Max initial illuminance at site boundary | Max beyond the boundary | Max % uplight | |
|---|---|---|---|---|
| LZ1Parks and rural areas | < 1 lux | N/A | 0% | |
| LZ2Residential areas | 1.1 lux | < 1 lux at 3 m | 2% | |
| LZ3All other areas | 2.2 lux | < 1 lux at 4.5 m | 5% |
Every project must be classified under one of the lighting zones. Where site boundaries abut public rights-of-way, light trespass requirements may be met relative to the curb line instead of the site boundary.
Per luminaire type. Quantity × lumens gives the total; the upward share is what the credit measures.
The credit counts only the uplight that leaves the site. A luminaire fully screened by a parapet or canopy contributes little even if its upward flux is high — but that reduction must be defensible from the design, not assumed. Leave at 100% unless you can show otherwise.
From the photometric calculation for the scheme.
≤ 2.2 lux ✓
< 1 lux at 4.5 m ✓
Where site boundaries abut public rights-of-way, light trespass requirements may be met relative to the curb line instead of the site boundary.
These two are alternatives — meet either one.
🏅 One credit point maximum, at Design and at Construction Rating.
LBo-10 covers interior as well as exterior lighting — not exterior alone. The two interior requirements are alternatives to one another.
Source
Pearl Building Rating System, Version 1.0, April 2010 — credit LBo-10, page 72 of 223. The zone classification itself is taken by the manual from the IECC 2009 Exterior Lighting Table 505.6.2(1).Outstanding